11
11.13 T: Motor Tuning
YASKAWA SIEPYEULA5001C LA500 Technical Manual 269
11.13 T: Motor Tuning
T1: Induction Motor Auto-Tuning
No.
(Hex.)
Name Description
Default
(Range)
Ref.
T1-01
(0701)
Tuning Mode Selection
Sets the type of Auto-Tuning.
0 : Rotational Auto-Tuning
1 : Stationary Auto-Tuning 1
2 : Stationary Line-Line Resistance
Determined by A1-02
(Determined by A1-02)
367
T1-02
(0702)
Motor Rated Power
Uses the units set in o1-58 [Motor Power Unit Selection] to set the motor rated output
power.
Determined by o2-04
(0.00 - 650.00 kW)
367
T1-03
(0703)
Motor Rated Voltage
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output
motors.
400 V Class: 400.0 V
(400 V Class: 0.0 - 511.0
V)
367
T1-04
(0704)
Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04
(10% to 200% of the
drive rated current)
367
T1-05
(0705)
Motor Base Frequency
Sets the base frequency (Hz) of the motor.
50.0 Hz
(0.0 - 120.0 Hz)
368
T1-06
(0706)
Number of Motor Poles
Sets the number of motor poles.
4
(2 to 48)
368
T1-07
(0707)
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
-1
(r/min)).
1450 min
-1
(r/min)
(0 - 24000 min
-1
(r/min))
368
T1-08
(0708)
Motor no-load voltage
Sets the no-lead voltage of the motor.
40% of motor nominal
current
368
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV

Table of Contents