4.3 Set up the Drive with User-Parameter Menu
80 YASKAWA SIEPYEULA5001C LA500 Technical Manual
4.3 Set up the Drive with User-Parameter Menu
Drive parameters are in letter groups from A to U. Setup Mode contains only the most frequently used
parameters to help you set up the drive more easily.
Figure 4.5 Parameters in General-Purpose Setup Mode
Table 4.2 shows the parameters available in Setup Mode. To access parameters not shown in the Setup Mode, use
the menu.
Table 4.2 Parameters in General-Purpose Setup Mode
User Parameter Parameter Name
A2-01 A1-00 Language Selection
A2-02 A1-02 Control Method Selection
A2-03 d1-18 Speed Reference Selection Mode
A2-04 d1-19 Nominal Speed
A2-05 d1-23 Releveling Speed
A2-06 d1-24 Inspection Operation
A2-07 d1-25 Rescue Operation Speed
A2-08 d1-26 Leveling Speed
A2-09 d1-01 Speed Reference 1
A2-10 d1-02 Speed Reference 2
A2-11 d1-03 Speed Reference 3
A2-12 d1-04 Speed Reference 4
A2-13 d1-05 Speed Reference 5
A2-14 d1-06 Speed Reference 6
A2-15 d1-07 Speed Reference 7
A2-16 d1-08 Speed Reference 8
A2-17 d1-28 Nominal/Leveling Spd Detection
A2-18 d1-29 Inspection Speed Detection
A2-19 C1-01 Acceleration Time 1
A2-20 C1-02 Deceleration Time 1
A2-21 C2-01 S-Curve @ Start of Acceleration
A2-22 C2-02 S-Curve @ End of Acceleration
A2-23 C2-03 S-Curve @ Start of Deceleration
A2-24 C2-04 S-Curve @ End of Deceleration
A2-25 C2-05 Jerk @ Levelig
A2-26 E2-03 Motor No-Load Current
A2-27 S1-02 DC-Injection @ Start
A2-28 S1-03 DC-Injection @ Stop
A2-29 S1-06 Brake Open Delay
A2-30 S1-07 Brake Close Delay