Parameter Details
12
12.9 o: Keypad-Related Settings
YASKAWA SIEPYEULA5001C LA500 Technical Manual 353
1 : Enabled
The drive detects EP24v when the main circuit power supply voltage decreases.
Note:
A minor fault signal is not output from H2-xx = 10 [MFDO Function Selection = Alarm].
■ o2-27: bCE Detection Selection
No.
(Hex.)
Name Description
Default
(Range)
o2-27
(1565)
Expert
bCE Detection Selection
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in
Bluetooth Mode.
3
(0 - 4)
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
◆ o3: Copy Function
o3 parameters set the operation of the parameter backup function.
■ o3-01: Copy Keypad Function Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-01
(0515)
Copy Keypad Function
Selection
Sets the function that saves and copies drive parameters to a different drive with the keypad.
0
(0 - 3)
0 : Copy Select
1 : Backup (drive → keypad)
The parameter setting values are read from the drive and saved in the keypad.
2 : Restore (keypad → drive)
Copies the parameter setting values saved in the keypad to a different drive.
3 : Verify (check for mismatch)
Makes sure that the parameter setting values in the drive agree with the parameters saved in the keypad.
■ o3-02: Copy Allowed Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-02
(0516)
Copy Allowed Selection
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive →
keypad)].
0
(0, 1)
Note:
When you select [Parameter Backup] on the keypad menu screen to do the backup function, the drive automatically sets o3-02 = 1.
0 : Disabled
1 : Enabled
■ o3-04: Select Backup/Restore Location
No.
(Hex.)
Name Description
Default
(Range)
o3-04
(0B3E)
Select Backup/Restore
Location
Sets the storage location for drive parameters when you back up and restore parameters. This
parameter is only available when using an LCD keypad.
0
(0 - 3)
You can use the LCD keypad to make a maximum of 4 parameter backup sets.
0 : Memory Location 1
1 : Memory Location 2