12.6 H: Terminal Function Selection
320 YASKAWA SIEPYEULA5001C LA500 Technical Manual
51: Output Contactor Control
Setting Value Function Description
51 Output Contactor Control
Assigning this command to an output terminal can send a signal to the controller to close the output contactor. The output
contactor should open when the terminal is released.
Closed : Close output contactor
54: Light Load Direction
Setting Value Function Description
54 Light Load Direction
Indicates the light load direction detected during emergency operation with light load search. When the terminal is closed the
light load direction is up, when it is open the light load direction is down.
Closed : Light load direction is up
Open : Light load direction is down
58: Safe Disable Status
Setting Value Function Description
58 Safe Disable Status
This terminal closes if the Safe Disable inputs H1-HC are closed and opens when terminals H1-HC are open.
Closed : Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open : Safe Disable terminals H1-HC and H2-HC are closed (normal operation)
100 to 158: Inverse output of 0 to 58
Setting Value Function Description
100 - 158 Inverse output of 0 to 58
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which function to
inversely output.
For example, set H2-xx = 10E for the inverse output of E [Fault].
H4: Analog Outputs
H4 parameters set the drive analog monitors. These parameters select monitor parameters, adjust gain and bias,
and select output signal levels.
Calibrate Meters Connected to MFAO Terminal AM
Use these parameters to calibrate meters connected to terminal AM:
H4-02 [Terminal AM Analog Output Gain]
H4-03 [Terminal AM Analog Output Bias]
Set these parameters where the output voltage of 10 V are 100% of the signal level.
No. Name Range Default
H4-02 Terminal AM Analog Output Gain -999.9 - +999.9% 100.0%
H4-03 Terminal AM Analog Output Bias -999.9 - +999.9% 0.0%
Figure 12.22 and Figure 12.23 show the gain and bias.
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV