2.5 Drive Models and Drive Watt Loss
YASKAWA SIEPYEULA5001C LA500 Technical Manual 33
Drive Watt Loss (with Built-in EMC Filter)
Three-Phase 200 V Class
Table 2.6 Drive Watt Loss (HD, Fc = 2 kHz)
Model
Rated Output Current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
2018E 17.6 2 37 83 120
2025E 25.0 2 46 163 209
2033E 33.0 2 56 200 256
2047E 47.0 2 78 269 347
2060E 60.0 2 109 411 520
2075E 75.0 2 133 439 572
Table 2.7 Drive Watt Loss (HD, Fc = 8 kHz [Default Setting])
Model
Rated Output Current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
2018E 21 8 41 108 149
2025E 30 8 50 187 237
2033E 42 8 61 232 293
2047E 56 8 86 318 404
2060E 70 8 120 473 593
2075E 82 8 149 525 674
Three-Phase 400 V Class
Table 2.8 Drive Watt Loss (HD, Fc = 2 kHz)
Model
Rated Output Current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
4009E 9.2 2 29 60 89
4015E 14.8 2 52 126 178
4018E 18 2 57 152 209
4024E 24 2 73 191 264
4031E 31 2 89 256 345
4039E 39 2 119 338 457
4045E 45 2 128 328 456
Table 2.9 Drive Watt Loss (HD, Fc = 8 kHz [Default Setting])
Model
Rated Output Current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
4009E 9.2 8 34 85 119
4015E 14.8 8 59 166 225
4018E 18 8 65 200 265
4024E 24 8 84 255 339
4031E 31 8 103 338 441
4039E 39 8 137 442 579
4045E 45 8 149 446 595