Parameter List
11
11.4 b: Application
YASKAWA SIEPYEULA5001C LA500 Technical Manual 241
11.4 b: Application
b1: Operation Mode Selection
No.
(Hex.)
Name Description
Default
(Range)
Ref.
b1-02
(0181)
Run Command Selection
1
Sets the Up/Down command source in Remote mode. Wire the motor so the elevator
goes up when an Up command is issued.
0 : Keypad
1 : Control Circuit Terminal
1
(0 - 1)
284
b1-03
(0182)
Stopping Method
Selection
Sets the method to stop the motor after removing a Run command or entering a Stop
command.
0 : Ramp to Stop
1 : Coast to Stop
0
(0 - 1)
284
b1-08
(0187)
Run Command Select in
PRG Mode
Sets the conditions for the drive to accept an Up/Down command entered from an
external source when using the keypad to set parameters.
0 : Disregard RUN while Programming
1 : Accept RUN while Programming
1
(0 - 1)
284
b1-14
(01C3)
Phase Order Selection
Sets the phase order for output terminals U/T1, V/T2, and W/T3. This parameter can
align the Forward Run command from the drive and the forward direction of the motor
without changing wiring.
0 : Standard
1 : Switch Phase Order
0
(0, 1)
285
b4: Timer Function
No.
(Hex.)
Name Description
Default
(Range)
Ref.
b4-01
(01A3)
Timer Function ON-
Delay Time
Sets the ON-delay time for the timer input.
0.0 s
(0.0 - 3000.0 s)
286
b4-02
(01A4)
Timer Function OFF-
Delay Time
Sets the OFF-delay time for the timer input.
0.0 s
(0.0 - 3000.0 s)
286
b6: Dwell Function
No.
(Hex.)
Name Description
Default
(Range)
Ref.
b6-01
(01B6)
Expert
Dwell Reference at Start
Sets the output frequency that the drive will hold momentarily when the motor starts.
0.0
(Determined by A1-02)
286
b6-02
(01B7)
Expert
Dwell Time at Start
Sets the length of time that the drive will hold the output frequency when the motor
starts.
0.0 s
(0.0 - 10.0 s)
286
b6-03
(01B8)
Expert
Dwell Reference at Stop
Sets the output frequency that the drive will hold momentarily when ramping to stop the
motor.
0.0
(Determined by A1-02)
287
b6-04
(01B9)
Expert
Dwell Time at Stop
Sets the length of time for the drive to hold the output frequency when ramping to stop
the motor.
0.0 s
(0.0 - 10.0 s)
287
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV