Parameter List
11
11.14 U: Monitors
YASKAWA SIEPYEULA5001C LA500 Technical Manual 273
No.
(Hex.)
Name Description MFAO Signal Level
U2-16
(07E1)
q-Axis Current@Fault
Shows the q-Axis current of the motor at the fault that occurred most recently.
Use U6-01 [Iq Secondary Current] to monitor the q-Axis current of the motor.
Unit: 0.1 %
No signal output available
U2-17
(07E2)
d-Axis Current@Fault
Shows the d-Axis current of the motor at the fault that occurred most recently.
Use U6-02 [Id ExcitationCurrent] to monitor the d-Axis current of the motor.
Unit: 0.1%
No signal output available
◆ U3: Fault History
No.
(Hex.)
Name Description MFAO Signal Level
U3-01
(0090)
1st MostRecent Fault
Shows the fault history of the most recent fault.
No signal output available
U3-02
(0091)
2nd MostRecent Fault
Shows the fault history of the second most recent fault.
No signal output available
U3-03
(0092)
3rd MostRecent Fault
Shows the fault history of the third most recent fault.
No signal output available
U3-04
(0093)
4th MostRecent Fault
Shows the fault history of the fourth most recent fault.
No signal output available
U3-05
(0804)
5th MostRecent Fault
Shows the fault history of the fifth most recent fault.
No signal output available
U3-06
(0805)
6th MostRecent Fault
Shows the fault history of the sixth most recent fault.
No signal output available
U3-07
(0806)
7th MostRecent Fault
Shows the fault history of the seventh most recent fault.
No signal output available
U3-08
(0807)
8th MostRecent Fault
Shows the fault history of the eighth most recent fault.
No signal output available
U3-09
(0808)
9th MostRecent Fault
Shows the fault history of the ninth most recent fault.
No signal output available
U3-10
(0809)
10th MostRecentFault
Shows the fault history of the tenth most recent fault.
No signal output available
U3-11
(0094)
ElapsedTime@1stFault
Shows the cumulative operation time when the most recent fault occurred.
Unit: 1 h
No signal output available
U3-12
(0095)
ElapsedTime@2ndFault
Shows the cumulative operation time when the second most recent fault occurred.
Unit: 1 h
No signal output available
U3-13
(0096)
ElapsedTime@3rdFault
Shows the cumulative operation time when the third most recent fault occurred.
Unit: 1 h
No signal output available
U3-14
(0097)
ElapsedTime@4thFault
Shows the cumulative operation time when the fourth most recent fault occurred.
Unit: 1 h
No signal output available
U3-15
(080E)
ElapsedTime@5thFault
Shows the cumulative operation time when the fifth most recent fault occurred.
Unit: 1 h
No signal output available
U3-16
(080F)
ElapsedTime@6thFault
Shows the cumulative operation time when the sixth most recent fault occurred.
Unit: 1 h
No signal output available
U3-17
(0810)
ElapsedTime@7thFault
Shows the cumulative operation time when the seventh most recent fault occurred.
Unit: 1 h
No signal output available
U3-18
(0811)
ElapsedTime@8thFault
Shows the cumulative operation time when the eighth most recent fault occurred.
Unit: 1 h
No signal output available