Parameter List
11
11.11 o: Keypad-Related Settings
YASKAWA SIEPYEULA5001C LA500 Technical Manual 265
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o4-23
(1550)
RUN
Expert
Date Format
Sets the date display format. This parameter is only available when using an LCD
keypad.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
0
(0 - 2)
357
o4-24
(310F)
RUN
Expert
bAT Detection Selection
Sets the operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM
[Keypad Time Not Set]. This parameter is only available when you use an LCD keypad.
0 : Disable
1 : Enable (Alarm Detected)
2 : Enable (Fault Detected)
0
(0 - 2)
357
o5: Log Function
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o5-01
(1551)
RUN
Expert
Log Start/Stop Selection
Sets the data log function. This parameter is only available when using an LCD keypad.
0 : OFF
1 : ON
0
(0 - 1)
360
o5-02
(1552)
RUN
Expert
Log Sampling Interval
Sets the data log sampling cycle. This parameter is only available when using an LCD
keypad.
1000 ms
(100 - 60000 ms)
360
o5-03
(1553)
RUN
Expert
Log Monitor Data 1
Sets the data log monitor. This parameter is only available when using an LCD keypad.
101
(000, 101 - 999)
360
o5-04
(1554)
RUN
Expert
Log Monitor Data 2
Sets the data log monitor. This parameter is only available when using an LCD keypad.
102
(000, 101 - 999)
360
o5-05
(1555)
RUN
Expert
Log Monitor Data 3
Sets the data log monitor. This parameter is only available when using an LCD keypad.
103
(000, 101 - 999)
361
o5-06
(1556)
RUN
Expert
Log Monitor Data 4
Sets the data log monitor. This parameter is only available when using an LCD keypad.
107
(000, 101 - 999)
361
o5-07
(1557)
RUN
Expert
Log Monitor Data 5
Sets the data log monitor. This parameter is only available when using an LCD keypad.
108
(000, 101 - 999)
361
o5-08
(1558)
RUN
Expert
Log Monitor Data 6
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
361
o5-09
(1559)
RUN
Expert
Log Monitor Data 7
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
361
o5-10
(155A)
RUN
Expert
Log Monitor Data 8
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
362
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV

Table of Contents

Other manuals for YASKAWA LA500

Related product manuals