Startup Procedure and Test Run
4
4.7 Setup Procedure for Elevator Applications
YASKAWA SIEPYEULA5001C LA500 Technical Manual 93
Multi-Speed Inputs 1
When d1-18 = 0, multi-function digital inputs are preset as shown below.
Setting of d1-18 Speed Selection Set Value
S5 H1-05 3 Multi-Speed Reference 1
S6 H1-06 4 Multi-Speed Reference 2
S7 H1-07 5 Multi-Speed Reference 3
Different speed reference settings can be selected by combining the three digital inputs as shown in the table
below.
Parameters d1-19 through d1-26 are displayed only if d1-18 is set to 1 or 2.
Digital Inputs Selected Speed
Multi-Speed Reference 1 Multi-Speed Reference 2 Multi-Speed Reference 3 d1-18 = 0
0 (Off) 0 (Off) 0 (Off) Speed Reference 1 (d1-01)
1 (On) 0 (Off) 0 (Off) Speed Reference 2 (d1-02)
0 (Off) 1 (On) 0 (Off) Speed Reference 3 (d1-03)
1 (On) 1 (On) 0 (Off) Speed Reference 4 (d1-04)
0 (Off) 0 (Off) 1 (On) Speed Reference 5 (d1-05)
1 (On) 0 (Off) 1 (On) Speed Reference 6 (d1-06)
0 (Off) 1 (On) 1 (On) Speed Reference 7 (d1-07)
1 (On) 1 (On) 1 (On) Speed Reference 8 (d1-08)
Setting d1-18 = 0 :
Up to eight speed references can be set using parameters d1-01 to d1-08. The drive starts with an Up or Down
command, and stops when the Up or Down command is removed. When d1-18 = 0, parameters d1-19 through d1-
23 will not be displayed.
Separate Speed Inputs (d1-18 = 1)
Six different speed settings (defined in the parameters d1-19 to d1-24 and d1-26) can be set and selected using
four digital inputs. When d1-18 = 1, multi-function digital inputs are preset as shown below:
Setting of d1-18 Speed Selection Set Value Details
S3 H1-03 50 Nominal speed (d1-19)
S4 H1-04 54 Inspection speed (d1-24)
S5 H1-05 51 Intermediate speed (d1-20)
S6 H1-06 53 Leveling speed (d1-26)
Different speed settings can be selected depending on the assignment of the speed selection digital inputs (H1-xx)
as shown in the table below. Parameters d1-19 through d1-26 are displayed only if d1-18 is set to 1 or 2.
Leveling and Nominal Speed assigned
(H1-xx = 50 and H1-xx = 53)
Leveling Speed not assigned
(H1-xx 53)
Nominal Speed not assigned
(H1-xx 50)
Selected Speed
50 51 52 53 50 51 52 51 52 53
1 0 0 A 1 0 0 0 0 0 Nominal Speed (d1-19)
0 1 0 A 0 1 0 1 0 0 Intermediate Speed 1 (d1-20)
1 1 1 A 1 1 1 N/A N/A N/A Intermediate Speed 2 (d1-21)
0 1 1 A 0 1 1 1 1 0 Intermediate Speed 3 (d1-22)
0 0 1 A 0 0 1 0 1 0 Releveling Speed (d1-23)
0 0 0 1 0 0 0 A A A Leveling Speed (d1-26)
0 0 0 0 N/A N/A N/A N/A N/A N/A Zero Speed
0 = Off, 1 = On, A = no influence, N/A = Not available
Higher Speed has Priority and the Leveling Speed Input is Assigned (d1-18 = 1 and H1-xx = 53)