EasyManua.ls Logo

YASKAWA U1000 - Page 168

YASKAWA U1000
706 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
n
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note: T2-07 will be displayed when in OLV/PM.
No. Name Setting Range Default
T2-07 PM Motor Base Frequency 0.0 to 400.0 Hz 87.5 Hz
n
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No. Name Setting Range Default
T2-08 Number of PM Motor Poles 2 to 48 6
n
T2-09: PM Motor Base Speed
Enter the motor rated speed in r/min.
Note: T2-09 will be displayed when in AOLV/PM and CLV/PM.
No. Name Setting Range Default
T2-09 PM Motor Base Speed 0 to 24000 r/min 1750 r/min
n
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No. Name Setting Range Default
T2-10 PM Motor Stator Resistance 0.000 to 65.000 Ω Determined by T2-02
n
T2-11: PM Motor d-Axis Inductance
Enter the d-Axis inductance per motor phase.
No. Name Setting Range Default
T2-11 PM Motor d-Axis Inductance 0.00 to 600.00 mH Determined by T2-02
n
T2-12: PM Motor q-Axis Inductance
Enter the q-Axis inductance per motor phase.
No. Name Setting Range Default
T2-12 PM Motor q-Axis Inductance 0.00 to 600.00 mH Determined by T2-02
n
T2-13: Induced Voltage Constant Unit Selection
Selects the units used for setting the induced voltage coefficient.
No. Name Setting Range Default
T2-13 Induced Voltage Constant Unit Selection 0, 1 1
Setting 0: mV (r/min)
Setting 1: mV (rad/sec)
Note: If T2-13 is set to 0, then the drive will use E5-24 (Motor Induction Voltage Constant 2), and will automatically set E5-09 (Motor Induction
Voltage Constant 1 (Ke)) to 0.0. If T2-13 is set to 1, then the drive will use E5-09 and will automatically set E5-25 to 0.0.
n
T2-14: PM Motor Induced Voltage Constant (Ke)
Enter the motor induced voltage constant (Ke).
No. Name Setting Range Default
T2-14 PM Motor Induced Voltage Constant (Ke) 0.0 to 2000.0 Determined by T2-02
4.7 Auto-Tuning
168
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual