Register No. Contents
00E2H
oFC1o Contents (CN5-C)
bit 0 Option RAM Fault (oFC10)
bit 1 Option Operation Mode Fault (SLMOD) (oFC11)
bit 2 Unit Receive CRC Error (oFC12)
bit 3 Unit Receive Frame Error (oFC13)
bit 4 Unit Receive Abort Error (oFC14)
bit 5 Option Receive CRC Error (oFC15)
bit 6 Option Receive Frame Error (oFC16)
bit 7 Option Receive Abort Error (oFC17)
bit 8 to F Reserved
00E3H Reserved
00E4H
oFC5o Contents (CN5-C)
bit 0 Encoder Option AD Conversion Error (oFC50)
bit 1 Encoder Option Analog Circuit Error (oFC51 )
bit 2 Encoder Communication Timeout (oFC52 )
bit 3 Encoder Communication Data Error (oFC53)
bit 4 Encoder Error (oFC54)
bit 5 Resolver Error (oFC55)
bit 6 to F Reserved
00E5H to 00E9H Reserved
00EAH
Fault contents 11
bit 0 to 6 Reserved
bit 7 Damping Resistor Overheat (doH)
bit 8 Snubber Discharge Resistor Overheat (SoH)
bit 9 Internal Resistance Fault (Srr)
bit A to D Reserved
bit E Safety Circuit Fault (SCF)
bit F Reserved
00EBH to 00FAH Reserved
00FBH
Output Current
<2>
<1> Parameter o1-03, Digital Operator Display Selection, determines the units.
<2> Display is in the following units:
2o0028, 2o0042, and 4o0011 to 4o0027: 0.01 A units
2o0054 to 2o0248 and 4o0034 to 4o0720: 0.1 A units
4o0900 and 4o0930: 1 A units
<3> Communication error contents are saved until the fault is reset.
<4> Set the number of motor poles to parameter E2-04 or E5-04 depending on the motor being used.