Loading...
ELCB
(MCCB)
EMC filter Harmonic filter module
Three-
phase
power
supply
Motor
Ground
shielded line main circuit terminal
control circuit terminal
Drive
R/L1
S/L2
T/L3
IM
U/T1
W/T2
W/T3
PE
p2
n2
r
t
p2
n2
X
Y
Z
X
Y
Z
X1
Y1
Z1
X1
Y1
Z1
r1/
11
1/
t1/
21
31
Figure D.7 Wiring Diagram for EMC (Models 4o0720 to 4o0930)
n
EMC Filters
Install the drive with the EMC filters listed in Table D.1 in to comply with the IEC/EN 61800-3 requirements.
Table D.2 IEC/EN 61800-3 Filters
Model Type Manufacturer
Rated Current
(A)
Weight (kg)
Dimensions
[W × H × D] mm
Y × X
(mm)
Figure
4o0477
B84143B1000S080
EPCOS
1000 18.5 410 × 140 × 260 235 × 240 Figure D.8
4o0590
B84143B1000S080
1000 18.5 410 × 140 × 260 235 × 240 Figure D.8
4o0720
B84143B1600S080
1600 24.5 490 × 140 × 260 235 × 240 Figure D.9
4o0900
B84143B1600S080
1600 24.5 490 × 140 × 260 235 × 240 Figure D.9
4o0930
B84143B1600S080
1600 24.5 490 × 140 × 260 235 × 240 Figure D.9
D.2 European Standards
654
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual

Table of Contents