EasyManuals Logo

Zebra TC75 Integrator Guide

Zebra TC75
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
4 - 16 TC75 Integrator Guide
Composite AB
UCC Link Mode
Link Flag ignored - 1D component is transmitted regardless of whether a 2D component is detected.
Always Linked - 1D and the 2D components are transmitted. If 2D is not present, the 1D component is
not transmitted.
Auto Discriminate - the digital scanner determines if there is a 2D portion, then transmits the 1D
component, as well as the 2D portion if present. (default).
Discrete 2 of 5
Length1 - Use to set decode lengths (default - 0). See Decode Lengths on page 4-19 for more information.
Length2 - Use to set decode lengths (default - 14). See Decode Lengths on page 4-19 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
GS1 DataBar Limited
GS1 Limited Security Level -
GS1 Security Level 1 - This setting allows the scanner to operate in its most aggressive state, while
providing sufficient security in decoding most “in-spec” bar codes.
GS1 Security Level 2 - This setting eliminates most misdecodes (default).
GS1 Security Level 3 - Select this option if Security level 2 fails to eliminate misdecodes.
•GS1 Security Level 4 - If Security Level 3 is selected and misdecodes still occur, select this security level.
Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar
codes. Selecting this level of security significantly impairs the decoding ability of the scanner. If this level
of security is needed, try to improve the quality of the bar codes.
HAN XIN
HAN XIN Inverse
Disable - Disables decoding of HAN XIN inverse bar codes (default).
Enable - Enables decoding of HAN XIN inverse bar codes.
•Auto - Decodes both HAN XIN regular and inverse bar codes.
Interleaved 2 of 5
Check Digit
No Check Digit - A check digit is not used. (default)
USS Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Uniform Symbology Specification (USS) check digit algorithm.
OPCC Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Optical Product Code Council (OPCC) check digit algorithm.
Length1 - Use to set decode lengths (default - 14). See Decode Lengths on page 4-19 for more information.
Length2 - Use to set decode lengths (default - 10). See Decode Lengths on page 4-19 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Report Check Digit - Transmit Interleaved 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send Interleaved 2 of 5 data with check digit (default - disabled).

Table of Contents

Other manuals for Zebra TC75

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra TC75 and is the answer not in the manual?

Zebra TC75 Specifications

General IconGeneral
Display Size4.7 inches
Resolution1280 x 720 pixels
Operating SystemAndroid
Battery Capacity4620 mAh
Cellular Connectivity4G LTE
GPSYes
Humidity5% to 95% non-condensing
Camera8 MP rear camera
Wireless ConnectivityWi-Fi 802.11 a/b/g/n
RuggednessMIL-STD-810G
Operating Temperature-20° C to 50° C
Barcode Scanner1D/2D imager
RAM1 GB
Storage8 GB
Expandable Storageup to 32 GB microSD
Dimensions6.3 x 3.3 x 1.1 inches

Related product manuals