DataWedge 4 - 17
I2of5 Security Level - Options: I2of5 Security level 0, I2of5 Security Level 1, I2of5 Security Level 2 and
I2of5 Security Level 3 (default - I2of5 Security level 1).
Convert ITF-14 To EAN13 - Convert 14-character Interleaved 2 of 5 bar codes to EAN-13, and transmit as
EAN-13. The Interleaved 2 of 5 bar code must be enabled and must have a leading zero and a valid EAN-13
check digit. A check in the checkbox indicates that the option is enabled (default - disabled).
I2of5 Reduced Quiet Zone - Enables decoding of margin-less I2of5 bar codes.
Matrix 2 of 5
Length1 - Use to set decode lengths (default - 10). See Decode Lengths on page 4-19 for more information.
Length2 - Use to set decode lengths (default - 0). See Decode Lengths on page 4-19 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
Report Check Digit - Transmit Matrix 2 of 5 data with or without the check digit. A check in the checkbox
indicates to send Matrix 2 of 5 data with check digit (default - enabled).
Verify Check Digit - Enable this feature to check the integrity of all Matrix 2 of 5 symbols to verify that the
data complies with a specified check digit algorithm (default - enabled).
MSI
Check Digit - With MSI symbols, one check digit is mandatory and always verified by the reader. The second
check digit is optional.
One Check Digit - Verify one check digit (default).
Two Check Digits - Verify two check digits.
Check Digit Scheme - Two algorithms are possible for the verification of the second MSI check digit. Select
the algorithm used to encode the check digit.
Mod-11-10 - First check digit is MOD 11 and second check digit is MOD 10 (default).
Mod-10-10 - Both check digits are MOD 10.
Length 1 - Use to set decode lengths (default - 4). See Decode Lengths on page 4-19 for more information.
Length 2 - Use to set decode lengths (default - 55). See Decode Lengths on page 4-19 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Report Check Digit - Transmit MSI data with or without the check digit. A check in the checkbox indicates to
send MSI data with check digit (default - disabled).
Trioptic 39
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
UK Postal (RS507)
Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the checkbox
indicates to send UK Postal data with check digit (default - disabled).

Table of Contents

Other manuals for Zebra TC75

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra TC75 and is the answer not in the manual?

Zebra TC75 Specifications

General IconGeneral
Display Size4.7 inches
Resolution1280 x 720 pixels
Operating SystemAndroid
Battery Capacity4620 mAh
Cellular Connectivity4G LTE
GPSYes
Humidity5% to 95% non-condensing
Camera8 MP rear camera
Wireless ConnectivityWi-Fi 802.11 a/b/g/n
RuggednessMIL-STD-810G
Operating Temperature-20° C to 50° C
Barcode Scanner1D/2D imager
RAM1 GB
Storage8 GB
Expandable Storageup to 32 GB microSD
Dimensions6.3 x 3.3 x 1.1 inches