Parameter listing
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Basic signals for monitoring the drive.Actual values1
All parameters in this group are read-only unless
otherwise noted.
- / real32Measured or estimated motor speed depending on
which type of feedback is used (see parameter 90.41
Motor speed used1.1
Motor feedback selection. A filter time constant for
this signal can be defined by parameter 46.11 Filter
time motor speed.
- / -Measured or estimated motor speed. For scaling, see
parameter 46.1.
-30000.00 ...
30000.00 rpm
- / real32Estimated motor speed in rpm. A filter time constant
for signal can be defined by parameter 46.11 Filter time
motor speed.
Motor speed
estimated
1.2
- / -Estimated motor speed. For scaling, see parameter
46.1.
-30000.00 ...
30000.00 rpm
- / real32Shows the value of 1.1 Motor speed used in percent of
the synchronous speed of the motor.
Motor speed %1.3
- / -Measured or estimated motor speed. For scaling, see
parameter 46.1.
-1000.00 ... 1000.00
%
- / real32Speed of encoder 1 in rpm. A filter time constant for
this signal can be defined by parameter 46.11 Filter
time motor speed.
Encoder 1 speed
filtered
1.4
- / -Encoder 1 speed. For scaling, see parameter 46.1.-30000.00 ...
30000.00 rpm
- / real32Speed of encoder 2 in rpm. A filter time constant for
this signal can be defined by parameter 46.11 Filter
time motor speed.
Encoder 2 speed
filtered
1.5
- / -Encoder 2 speed. For scaling, see parameter 46.1.-30000.00 ...
30000.00 rpm
- / real32Estimated drive output frequency in Hz. A filter time
constant for this signal can be defined by parameter
46.12 Filter time output frequency.
Output frequency1.6
- / -Estimated output frequency. For scaling, see parameter
46.2.
-600.00 ... 600.00 Hz
- / real32Measured (absolute) motor current in A.Motor current1.7
- / -Motor current. For scaling, see parameter 46.5.0.00 ... 30000.00 A
- / real32Motor current (drive output current) in percent of the
nominal motor current.
Motor current % of
motor nom
1.8
1 = 1 % / 10 = 1 %Motor current.0.0 ... 1000.0 %
- / real32Motor torque in percent of the nominal motor torque.
See also parameter 1.30 Nominal torque scale.
Motor torque1.10
A filter time constant for this signal can be defined by
parameter 46.13 Filter time motor torque.
- / -Motor torque. For scaling, see parameter 46.3.-1600.0 ... 1600.0 %
134 Parameters