EasyManua.ls Logo

ABB ACS880 N5700 Series - Example 1 - Pulley Transmission with Position Feedback from Motor Encoder

ABB ACS880 N5700 Series
662 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Load (C)Load shaft (B)Motor shaft (A)Feedback
Linear (rotary) en-
coder
Rotary encoderRotary encoder
Gear ratio× Load
revs/ Load encoder
revs
Gear ratio1Load encoder scale
*Modulo operation is typically used for repeating rotary movement (eg. rotary table). The
modulo settings here provide the feed constant as a repeated position range (eg. actual
position in the range of 0…360, when Feed constant = 360).
Note: The combination (product) of Load gear and Feed constant can be set in either one
of these to reduce the number of required parameter settings.
Example 1 Pulley transmission with position feedback from motor
encoder
Drive-side pulley diameter: 200 mm
Load-side pulley diameter: 500 mm
Load units:
1 unit = 1.000 degree / 360 degrees as
modulo (1 turn of load-side pulley)
Position feedback: Motor encoder
Speed feedback: Motor encoder
ENC
1
M
ACS880
FEN-xx
Load gear = 86.14/86.15 = Load revs/Load encoder revs = 1/Gear ratio = 200/500 (or 1/1,
see note)
Feed constant = 86.16/86.17 = Load units/Load revs = 360/1 (or 360/1 × 200/500, see note)
Modulo range = 86.18/86.19 = Gear ratio = 500/200
Load encoder scale = 86.21/86.22 = Motor revs/Load encoder revs = 1/1
Note: The figure in brackets is an alternative factor that combines the effects of Feed
constant and Load gear.