Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Information on drive hardware, firmware and
application program.
System info7
All parameters in this group are read-only.
- / uint16Type of the drive/inverter unit.Drive rating id7.3
0 / uint32Firmware identification.
The format is AINFX, where X denotes the control unit
type
Firmware name7.4
(2 or B = BCU-x2, 6 or C = ZCU-12/14).
0 / uint32Version number of the firmware.
The format is A.BB.C.D, where A = major version, B =
minor version, C = patch (ie. firmware variant code), D
= 0.
Firmware version7.5
0 / uint32Name of the firmware loading package.
The format is AINLX, where X denotes the control unit
type (2 or B = BCU-x2, 6 or C = ZCU-12/14).
Loading package
name
7.6
0 / uint32Version number of the firmware loading package. See
parameter 7.5.
Loading package
version
7.7
0 / uint32Version number of the firmware bootloader.Bootloader version7.8
- / uint32Microprocessor load in percent.Cpu usage7.11
1 = 1 % / 1 = 1 %Microprocessor load.0...100 %
- / uint16Version number of the power unit logic.
The value of FFFF indicates that the version numbers
of parallel-connected power units are different. See the
drive information on the control panel.
PU logic version
number
7.13
- / uint32Version name of the FPGA logic of the control unit.FPGA logic version
name
7.14
- / uint16Version number of the FPGA logic of the control unit.FPGA logic version
number
7.15
- / uint16
(Only visible with option +N8010 [application
programmability])
Application
environment status
1
7.21
Shows which tasks of the application program are
running.
See the
Drive (IEC 61131-3) application programming
manual
(3AUA0000127808 [English]).
1 = Pre-task running.Pre taskb0
1 = Task 1 running.Appl task1b1
1 = Task 2 running.Appl task2b2
1 = Task 3 running.Appl task3b3
Reservedb4…14
1 = Task monitoring enabled.Task monitoringb15
1 = 10000h…FFFFh
Parameters 169