Fieldbus adapter B configuration.FBA B settings54
- / uint16Displays the type of the connected fieldbus adapter
module. 0 = Module is not found or is not properly
FBA B type54.1
connected, or is disabled by parameter 50.31 FBA B
enable; 1 = FPBA; 32 = FCAN; 37 = FDNA; 101 = FCNA,
128 = FENA-11/21; 135 = FECA; 136 = FEPL; 485 = FSCA.
This parameter is read-only.
- / uint16Parameters 54.0254.26 are adapter module-specific.
For more information, see the documentation of the
FBA B Par254.2
fieldbus adapter module. Note that not all of these
parameters are necessarily in use.
1 = 1 / 1 = 1Fieldbus adapter configuration parameter.0.0 ... 65535.0
- / uint16See parameter 54.2 FBA B Par2.FBA B Par2654.26
1 = 1 / 1 = 1Fieldbus adapter configuration parameter.0.0 ... 65535.0
Done / uint16Validates any changed fieldbus adapter module
configuration settings. After refreshing, the value
reverts automatically to Done.
FBA B par refresh54.27
Note: This parameter cannot be changed while the
drive is running.
0Refreshing done.Done
1Refreshing.Refresh
0 / uint16Displays the parameter table revision of the fieldbus
adapter module mapping file (stored in the memory of
FBA B par table ver54.28
the drive). In format axyz, where ax = major table
revision number; yz = minor table revision number.
This parameter is read-only.
1 = 1Parameter table revision of adapter module.0000…FFFFh
- / uint16Displays the drive type code in the fieldbus adapter
module mapping file (stored in the memory of the
drive).
FBA B drive type
code
54.29
This parameter is read-only.
1 = 1 / 1 = 1Drive type code stored in the mapping file.0...65535
- / uint16Displays the fieldbus adapter module mapping file
revision stored in the memory of the drive in decimal
format.
FBA B mapping file
ver
54.30
This parameter is read-only.
1 = 1 / 1 = 1Mapping file revision.0...65535
- / uint16Displays the status of the fieldbus adapter module
communication.
D2FBA B comm
status
54.31
0Adapter is not configured.Not configured
1Adapter is initializing.Initializing
2A timeout has occurred in the communication between
the adapter and the drive.
Time out
392 Parameters