Parameters and firmware blocks
155
24
Firmware block:
SPEED REF SEL
(23)
Selects the sources for two speed
references, REF1 or REF2, from a
selection list. Also shows the values
of both speed references.
The sources can alternatively be
selected with value pointer
parameters. See firmware block
SPEED REF MOD on page 156.
Block outputs located in other
parameter groups
3.01 SPEED REF1 (page 101)
3.02 SPEED REF2 (page 101)
24.01 SPEED REF1 SEL FW block: SPEED REF SEL (see above)
Selects the source for speed reference 1 (3.01 SPEED REF1).
Source for speed reference 1/2 can also be selected by value pointer parameter 24.03 SPEED REF1
IN / 24.04 SPEED REF2 IN.
(0) ZERO Zero reference.
(1) AI1 Analogue input AI1.
(2) AI2 Analogue input AI2.
(3) FBA REF1 Fieldbus reference 1.
(4) FBA REF2 Fieldbus reference 2.
(5) D2D REF1 Drive to drive reference 1.
03.03 SPEEDREF
RAMP IN
3.01 SPEED REF1
3.02 SPEED REF2
24.05 SPEED REF 1/2 SEL
24.06 SPEED SHARE
24.07 SPEEDREF NEG ENA
1
-1
24.09 CONST SPEED ENA
24.10 SPEED REF JOG1
24.11 SPEED REF JOG2
10.13 FB CW USED
bit 10 JOGGING
06.02 STATUS WORD 2
bit 5 JOGGING
24.08 CONST SPEED
x
x
20.03 POS SPEED ENA
0
20.02 MINIMUM SPEED
20.04 NEG SPEED ENA
0
06.02 STATUS WORD 2
bit 12 RAMP IN 0
Local speed reference
06.01 STATUS WORD 1 bit 11
LOCAL PANEL
46.02 SPEED REF SAFE
SAFE SPEED COMMAND
06.01 STATUS WORD 1
bit 9 LOCAL FB
0
20.01 MAXIMUM SPEED
2.14 FBA MAIN REF1
24.12 SPEED REF MIN ABS
SPEED REF SEL
3
TLF 2 50 0 µse c (1)
24.01 SPEED REF1 SEL
[ AI1 ]
24.02 SPEED REF2 SEL
[ ZERO ]
3.01 SPEED REF1
3.02 SPEED REF2