Drive programming using PC tools
33
Operation modes
The DriveSPC tool offers the following operation modes:
Off-line
When the off-line mode is used without a drive connection, the user can
open a application program file (if exists).
modify and save the application program.
print the program pages.
When the off-line mode is used with a drive(s) connection, the user can
connect the selected drive to DriveSPC.
upload an application program from the connected drive (an empty template
which includes only the firmware blocks is available by default.)
download the configured application program to the drive and start the program
execution. The downloaded program contains the function block program and the
parameter values set in DriveSPC.
remove the program from the connected drive.
On-line
In the on-line mode, the user can
modify firmware parameters (changes are stored directly to the drive memory)
modify application program parameters (ie, parameters created in DriveSPC)
monitor the actual values of all function blocks in real time.