Parameters and firmware blocks
174
Group 32 TORQUE REFERENCE
Reference settings for torque control.
In torque control, the drive speed is limited between the defined minimum and
maximum limits. Speed-related torque limits are calculated and the input torque
reference is limited according to these limits. An OVERSPEED fault is generated if
the maximum allowed speed is exceeded.
3.12 TORQUE REF ADD
3.09 TORQ REF1
ZERO
AI1
AI2
FBA REF1
FBA REF2
D2D REF1
D2D REF2
32.01 TORQ REF1
SEL
ZERO
AI1
AI2
FBA REF1
FBA REF2
D2D REF1
D2D REF2
32.02 TORQ REF
ADD SEL
LOCAL CONTROL
LOCAL CONTROL REF
32.06 LOAD SHARE
32.04 MAXIMUM TORQ REF
32.05 MINIMUM TORQ REF
32.07 TORQ RAMP UP
32.08 TORQ RAMP DOWN
22.08 SPEED TRIP MARGIN
RUSHCTRL
1.01 SPEED ACT
20.01 MAXIMUM SPEED
20.02 MINIMUM SPEED
06.05 LIMIT WORD 1
bit 5 TLIM MAX SPEED
bit 6 TLIM MIN SPEED
06.05 LIMIT WORD 1
bit 3 TORQ REF MAX
bit 4 TORQ REF MIN
x
3.09 TORQ REF1
3.11 TORQ REF RUSHLIM