Standard function blocks
364
Inputs Counter input (CU): Boolean
Reset input (R): Boolean
Preset input (PV): DINT
Outputs Counter output (CV): DINT
Status output (Q): Boolean
CTUD
(10051)
Illustration
Execution time 1.40 µs
CTUD
97
TLA1 1 msec (1)
>CU
>CD
R
LD
PV
CV
CV(97)
QU
QU(9 7)
QD
QD(97)