Standard function blocks
382
Feedback & algorithms
CYCLET
(10074)
Illustration
Execution time 0.00 µs
Operation Output (OUT) is the time level of the CYCLET function block.
Inputs -
Outputs Output (OUT): DINT. 1 = 1 µs
DATA CONTAINER
(10073)
Illustration
Execution time 0.00 µs
Operation Output (OUT) is an array of data with values 1…99. The array can be used by the XTAB
and YTAB tables in the block FUNG-1V (page 383). The array is defined by selecting
“Define Pin Array Data” on the output pin in DriveSPC. Each value in the array must be
on a separate row. Data can also be read from an *.arr file.
Example:
Inputs -
Outputs The output data type and the number of coordinate pairs are selected by the user.
Output (OUT): DINT, INT, REAL or REAL24
CYCLET
58
TLA1 1 msec (1)
OUT
OUT(58)
DATA CONTAINER
(DINT) 59
TLA1 1 msec (1)
OUT
OUT(59)