Parameters and firmware blocks
256
90
Firmware block:
ENCODER
(3)
This block
activates the communication to
encoder interface 1/2
enables encoder emulation/echo
shows encoder 1/2 speed and
actual position.
Block inputs located in other
parameter groups
93.21 EMUL PULSE NR (page 269)
93.22 EMUL POS REF (page 269)
Block outputs located in other
parameter groups
1.08 ENCODER 1 SPEED (page 91)
1.09 ENCODER 1 POS (page 91)
1.10 ENCODER 2 SPEED (page 92)
1.11 ENCODER 2 POS (page 92)
2.16 FEN DI STATUS (page 99)
90.01 ENCODER 1 SEL FW block: ENCODER (see above)
Activates the communication to optional encoder/resolver interface 1.
Note: It is recommended that encoder interface 1 is used whenever possible since the data received
through that interface is fresher than the data received through interface 2. On the other hand, when
position values used in emulation are determined by the drive software, the use of encoder interface 2
is recommended as the values are transmitted earlier through interface 2 than through interface 1.
(0) None Inactive.
(1) FEN-01 TTL+ Communication active. Module type: FEN-01 TTL Encoder interface
Module. Input: TTL encoder input with commutation support (X32).
See parameter group 93.
(2) FEN-01 TTL Communication active. Module type: FEN-01 TTL Encoder interface
Module. Input: TTL encoder input (X31). See parameter group 93.
(3) FEN-11 ABS Communication active. Module type: FEN-11 Absolute Encoder
Interface. Input: Absolute encoder input (X42). See parameter group
91. Emulation is not possible with SSI or EnDat in the Continuous
mode (parameters 91.25 and 91.30).
(4) FEN-11 TTL Communication active. Module type: FEN-11 Absolute Encoder
Interface. Input: TTL encoder input (X41). See parameter group 93.
(5) FEN-21 RES Communication active. Module type: FEN-21 Resolver Interface.
Input: Resolver input (X52). See parameter group 92.
(6) FEN-21 TTL Communication active. Module type: FEN-21 Resolver Interface.
Input: TTL encoder input (X51). See parameter group 93.
ENCODER
15
TLF 8 25 0 µsec (1)
90.01 ENCODER 1 SEL
[ None ]
90.02 ENCODER 2 SEL
[ None ]
90.03 EMUL MODE SEL
[ Disabled ]
90.04 TTL ECHO SEL
[ Disabled ]
90.05 ENC CABLE FAULT
[ Fault ]
90.10 ENC PAR REFRESH
[ Done ]
93.21 EMUL PULSE NR
[ 0 ]
< 93.22 EMUL POS REF
[ POS ACT ]
(11 / 1.12)
1.08 ENCODER 1 SPEED
1.09 ENCODER 1 POS
1.10 ENCODER 2 SPEED
1.11 ENCODER 2 POS
2.16 FEN DI STATUS