Parameters and firmware blocks
145
Group 20 LIMITS
Definition of drive operation limits.
20
Firmware block:
LIMITS
(20)
Adjusts the drive speed, current and
torque limits, selects the source for
the positive/negative speed reference
enable command and enables the
thermal current limitation.
Block outputs located in other
parameter groups
3.20 MAX SPEED REF (page 102)
3.21 MIN SPEED REF (page 102)
20.01 MAXIMUM SPEED FW block: LIMITS (see above)
Defines the allowed maximum speed. See also parameter 22.08 SPEED TRIPMARGIN.
0…30000 rpm Allowed maximum speed.
20.02 MINIMUM SPEED FW block: LIMITS (see above)
Defines the allowed minimum speed. See also parameter 22.08 SPEED TRIPMARGIN.
-30000…0 rpm Allowed minimum speed.
LIMITS
27
MI S C_ 3 2 m sec (5)
20.01 MAXIMUM SPEED
(Drive value)
20.02 MINIMUM SPEED
(Drive value)
< 20.03 POS SPEED ENA
(Drive value)
< 20.04 NEG SPEED ENA
(Drive value)
20.05 MAXIMUM CURRENT
(Drive value)
20.06 MAXIMUM TORQUE
(Drive value)
20.07 MINIMUM TORQUE
(Drive value)
3.20 MAX SPEED REF
3.21 MIN SPEED REF