Starting the calibration procedure
Use this procedure to call for the Axis Calibration method on the FlexPendant.
NoteAction
On the ABB menu, tap Calibration.
xx1500000942
1
All mechanical units connected to the system are
shown with their calibration status.
2
Tap the mechanical unit in question.
xx1500000943
Continues on next page