M16 anchor
28,8Recommended loads: concrete C 20/25 – fck,cube = 25 N/mm², anchor HAS
Shear VRd HAS [kN]
i
The allowed range of embedment depth is shown in the setting details. The corresponding load
values can be calculated according to the simplified design method.
ii
With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the
type of loading and shall be taken from national regulations.
Basic design tensile resistance
xx1400000488
Service temperature range
Hilti HVU adhesive may be applied in the temperature ranges given below. An
elevated base material temperature may lead to a reduction of the design bond
resistance.
Maximum short term
base material temper-
ature
ii
Maximum long term
base material temper-
ature
i
Base material temper-
ature
Temperature range
+40 °C+24 °C-40 °C to +40 °CTemperature range 1
+80 °C+50 °C-40 °C to +80 °CTemperature range 2
+120 °C+72 °C-40 °C to +120 °CTemperature range 3
i
Long-term elevated base material temperatures are roughly constant over significant periods of
time.
ii
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a
result of diurnal cycling.
Continues on next page
280 Product manual - IRBT 2005
3HAC051130-001 Revision: F
© Copyright 2015 - 2018 ABB. All rights reserved.
7 Reference information
7.8 HILTI adhesive anchor
Continued