2.8 Lubrication
2.8.1 Replacing the grease cartridge in grease pump MEMOLUB
®
EPS
Overview
This section is based on the MEMOLUB
®
EPS user manual. It details how to
replace the grease cartridge.
Removing the grease cartridge
Illustration/NoteAction
xx1500001620
Remove the carriage side covers.1
xx1500000130
Disconnect the cartridge power cable from the
connector bracket on the carriage.
2
xx1500000131
Screw the complete cartridge counterclockwise
to remove it from its holder on the carriage.
3
Opening the grease pump
Illustration/NoteAction
Place the grease pump on a flat and clean
surface.
1
Continues on next page