EasyManua.ls Logo

ABB IRBT 2005 - Page 141

ABB IRBT 2005
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Illustration/NoteAction
xx1400001570
Push firmly with one hand on top of the grease
pump. With the other hand, hold the black base
and turn counterclockwise.
2
Pull the transparent housing and open it.3
Closing the grease pump
Illustration/NoteAction
xx1400001571
Hold the cranked black base, put on the trans-
parent housing and turn it clockwise.
1
When the closed position is reached you
should hear a "click".
2
Installing a new grease cartridge
Respect the following instructions to replace the grease cartridge:
Illustration/NoteAction
Open the MEMOLUB
®
as described before.1
xx1400001572
Pull-up the black rubber seal. Fill-in the
MEMOLUB
®
with a manual grease pump. This
manual operation is required only if the
MEMOLUB
®
has been used without a cart-
ridge, if the previous cartridge has run out of
grease. Place the pump nipple at the entry of
the MEMOLUB
®
, and pump until you see
grease coming out at the outlet. Two strokes
of the manual pump are usually enough.
2
Continues on next page
Product manual - IRBT 2005 141
3HAC051130-001 Revision: F
© Copyright 2015 - 2018 ABB. All rights reserved.
2 Installation and commissioning
2.8.1 Replacing the grease cartridge in grease pump MEMOLUB
®
EPS