Security 167
Available functions in the scripts are:
Function Parameters Description
getInput() RADIUS Access-Accept attributes as an input
object with key/value pairs
getInput() Error message (any text) Debug aid for Validate function of RADIUS permis-
sion script on Security settings dialog box, to show
customized errors for recognizing specific issues in
authorization.
User-specified errors are not shown in login dialog
box of NETA-21, instead, an Authorization error is
shown.
setResultJson(obj) Array of permission
strings
Must be called at the end of the script to generate
valid permissions for the user (empty return results
in Authorization error).
See below for examples of different typical permis-
sion sets, which are in NETA-21 web interface hid-
den behind user “roles” such as Guest, User, Drive
expert, Tool, and admin
log(text) Message Not visible in web interface, only for command line
debugging tests