Tension Electronics PFEA111/112, User Manual
Appendix D PFRL 101 - Designing the Load Cell Installation
D-14 3BSE029380R0101 Rev C
Material
A
B
C
D
SS 2387 stainless steel, DIN X4CrNiMo 16 5.
Corrosion resistance properties similar to AISI 304.
Accuracy
%Accuracy class ± 0.5
Repeatability error < ± 0.1
Compensated temperature range +20 - +80
(68 - 176)
°C
(°F)
Zero point drift 150 (83)
ppm/K
(ppm/
F)
Sensitivity drift 150 (83)
Working temperature range –10 - +80
(14 - 176)
°C
(°F)
Zero point drift 300 (167)
ppm/K
(ppm/
F)
Sensitivity drift 300 (167)
Storage temperature range –40 - +80
(–40 - 176)
°C
(°F)
Table D-2. Technical Data for Different Types of Load Cell PFRL 101
PFRL 101 Type Data Unit