Section G.8 Technical data load cell PFTL 201
3BSE029380R0101 Rev C G-11
G.8 Technical data load cell PFTL 201
Table G-3. Technical data for different types of load cell PFTL 201
PFTL 201,
type
Data Unit
Nominal load
Nominal load in measuring direc-
tion, F
nom
C/CE 10
(2250)
20
(4500)
50
(11200)
kN
(lbs)
D/DE 50
(11200)
100
(22500)
Permitted transverse load within the
accuracy, F
Vnom
C/CE 100
(22500)
200
(45000)
250
(56200)
kN
(lbs)
D/DE 500
(112000)
500
(112000)
Permitted axial load within the
accuracy, F
Anom
(h=300 mm)
C/CE 20
(4500)
20
(4500)
50
(11250)
kN
(lbs)
D/DE 100
(22500)
100
(22500)
Extended load in measuring direc-
tion with accuracy class ±1%, F
ext
C/CE 15
(3370)
30
(6740)
75
(16900)
kN
(lbs)
D/DE 75
(16900)
150
(33700)
Overload capacity
Maximal load in measuring direction
without permanent change of data,
F
max
C/CE 100
(11200)
200
(22500)
500
(56200)
kN
(lbs)
D/DE 500
(56200)
1000
(112000)
Spring constant
C/CE 1000
(5710)
1000
(5710)
1000
(5710)
kN/mm
(1000
lbs/inch)
D/DE 2000
(11400)
2000
(11400)
h
Pressductor
System

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PFEA 112 and is the answer not in the manual?

ABB PFEA 112 Specifications

General IconGeneral
BrandABB
ModelPFEA 112
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals