EasyManuals Logo

ABB PFEA 112 User Manual

ABB PFEA 112
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Tension Electronics PFEA111/112, User Manual
Section F.8 Technical Data Load Cell PFCL 201
3BSE029380R0101 Rev C F-11
F.8 Technical Data Load Cell PFCL 201
Table F-3. Technical Data
Type PFCL 201 Unit
Nominal loads
1)
Nominal load in measuring direction, F
nom
C/CD/CE
5
(1120)
10
(2250)
20
(4500)
50
(11200)
kN
(lbs)
Permitted transverse force within the
accuracy, F
Vnom
(for h = 300 mm)
2.5
(562)
5
(1120)
10
(2250)
25
(5620)
Permitted axial load within the accuracy,
F
Anom
(for h = 300 mm)
1.25
(281)
2.5
(562)
5
(1120)
12.5
(2810)
Extended load in measuring direction with
accuracy class ±1%, F
ext
7.5
(1690)
15
(3370)
30
(6740)
75
(16900)
Max permitted load
In the direction of measurement without
permanent change of data, F
max
2)
C/CD/CE
50
(11200)
100
(22500)
200
(45000)
500
3)
(112000) (kN)
(lbs)
In the transverse direction without permanent
change of data, F
Vmax
2)
(for h = 300 mm)
12.5
(2810)
25
(5620)
50
(11200)
125
(28100)
Spring constant C/CD/CE 250
(1430)
500
(2850)
1000
(5710)
2500
(14300)
kN/mm
(1000
lbs/inch)
Mechanical data
Length C/CD/CE 450
(17.7)
mm
(inch)
Width
C110
(4.3)
CD 138
(5.4)
CE 156
(6.1)
Height
C/CD/CE
125
(4.9)
Weight 37
(82)
kg
(lbs)
Material Stainless steel SIS 2387 DIN X4CrNiMo 165