EasyManua.ls Logo

ABB PFEA 112 - Page 184

ABB PFEA 112
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tension Electronics PFEA111/112, User Manual
Appendix F PFCL 201 - Designing the Load Cell Installation
F-12 3BSE029380R0101 Rev C
Figure F-6. Building Height
Accuracy
Accuracy class
C/CD/CE
± 0.5
%
Linearity deviation < ± 0.3
Repeatability error < ± 0.05
Hysteresis < 0.2
Compensated temperature range +20 - +80
(+68 - +176)
C
F)
Zero point drift 50
(28)
ppm/K
(ppm/F)
Sensitivity drift 100
(56)
Working temperature range –10 - +90
(+14 - +194)
C
F)
Zero point drift 100
(56)
ppm/K
(ppm/F)
Sensitivity drift 200
(111)
Storage temperature range –40 - +90
(–40 - +194)
C
F)
Table F-3. Technical Data
Type PFCL 201 Unit
Pressductor
System
h
h
1) Definitions of direction designations “
V
”and “
A
” in
F
V
and F
A
are given in Section A.2.1.
2) F
max
and F
Vmax
are allowed at the same time.
3) Max. permitted load for the load cell is 10 × F
nom
.
The overload capacity for the total installation may
be limited by the screws.

Table of Contents

Related product manuals