Alarm identifier
“Probable cause”
Alarm text Alarm
severity
Reporting state
(default setting)
E12XcEQF 2 Mbit/s extension board - defective Deferred Reported
E12XcUNI 2 Mbit/s extension board missing Prompt Reported
E12XcUPF 2 Mbit/s extension board - defective Prompt Reported
E31XcEQF 34 Mbit/s extension board (X2E3-V2) -
defective
Prompt Reported
E31XcUNI 34 Mbit/s extension board (X2E3-V2) missing Prompt Reported
E31XcUPF 34 Mbit/s extension board (X2E3-V2) -
defective
Prompt Reported
E31XcWUP Wrong 34 Mbit/s extension board inserted Prompt Reported
E32XcEQF 45 Mbit/s extension board (X2DS3-V2) -
defective
Deferred Reported
E32XcUNI 45 Mbit/s extension board (X2DS3-V2)
missing
Prompt Reported
E32XcUPF 45 Mbit/s extension board (X2DS3-V2) -
defective
Prompt Reported
E32XcWUP Wrong 45 Mbit/s extension board inserted Prompt Reported
IPcEQF
LAN unit failure - protected Deferred Reported
IPcUNI
LAN unit removed Deferred Reported
IPcUPF LAN unit failure Prompt Reported
IPcWUP Wrong LAN unit present Prompt Reported
PMcEQF Pluggable Module failure Deferred Reported
PMcUNI
Pluggable Module removed Deferred Reported
PMcUPF Unprotected Pluggable Module failure Prompt Reported
PMcWUP Wrong Pluggable Module present Prompt Reported
POWcLSV
Loss of secondary input voltage Deferred Reported
RPScOVERL Remote power supply box - load greater than
its capacity
Prompt Reported
RPScOPENC Remote power supply box - No electric
current
Prompt Reported
RPScFSD Remote power supply box - switched off
manually
Prompt Reported
RPScLEAK Remote power supply box - defective Prompt Reported
RPScHVOLT Remote power supply box - higher voltage Prompt Reported
RPScPS Remote power supply box - defective Prompt Reported
STM1XcEQF STM-1 interface extension board - Hardware
Failure
Deferred Reported
STM1XcUNI STM-1 interface extension board missing Prompt Reported
STM1XcUPF STM-1 interface extension board failure Prompt Reported
STM1XcWUP Wrong STM-1 interface extension board
inserted
Prompt Reported