Result: A list of all possible ports (or a ″-″ ) appears for the selected slot.
...................................................................................................................................................................................................
6
Select a port (or a ″-″) from the list for the Protection Reference.
Result: The Protection Reference for the timing source is selected (in case a port is
selected) or the Protection Reference for the timing source is unassigned (in case
″-″ is selected).
...................................................................................................................................................................................................
7
Click OK to confirm the current settings.
Result: The Assign Timing Reference to Timing Source window is closed and data
is sent to the network element.
...................................................................................................................................................................................................
8
Click Close.
Result: The Provisioned NE Timing Source Information window disappears.
Set QL prov, monitored, switch request, clear wait to restore
To set the quality level for an incoming (SDH) timing reference, set the Monitored
state of the timing reference, make a switch request or clear the Global Wait To
Restore Time follow this procedure:
...................................................................................................................................................................................................
1
Select Provisioning --> Timing --> Timing Sources
Result: The Provisioned NE Timing Source Information window appears.
...................................................................................................................................................................................................
2
Select a source that must be edited from the list and click Edit in the Sources field.
Result: The Edit Provisioned NE Timing Source window appears.
...................................................................................................................................................................................................
3
Select AUTO or a QL value from the list for QL Provisioned.
Result: A value is set for QL Provisioned.
...................................................................................................................................................................................................
4
Select Yes or No for Monitored.
Result: The monitoring of the reference of the timing source is set.
...................................................................................................................................................................................................
5
Important! A Switch Request can only be made if a protection reference is
assigned. This is only possible if the 1643 AM or 1643 AMS is working in the
STM-4 mode and STM-1 tributary units are present.
Timing provisioning
Provisioning timing sources
....................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
7-21
E ND OF STEPS
...................................................................................................................................................................................................