3 — Troubleshooting using network alarms
3-34 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Name: BatmDsx1CurrentUASs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of Unavailable Seconds
crosses the threshold.
Name: BatmDsx1TotalCSSs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of far-end Controlled Slip
Seconds crosses the threshold.
Name: BatmDsx1TotalESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of far-end Errored Seconds
crosses the threshold.
Name: BatmDsx1TotalLESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of Line Errored Seconds
crosses the threshold.
Name: BatmDsx1TotalPVCs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of Path Coding Violations
crosses the threshold.
Name: BatmDsx1TotalSEFSs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of far-end Severely Errored
Framing Seconds crosses the
threshold.
Name: BatmDsx1TotalSESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of far-end Severely Errored
Seconds crosses the threshold.
Name: BatmDsx1TotalUASs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the total
number of Unavailable Seconds
crosses the threshold.
Name: BatteryFail
Type: equipmentAlarm (3)
Probable cause: batteryFail (457)
Severity: Warning
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the battery
fails or is missing.
Name: BootLoaderFirmwareMismatchAlarm
Type: firmwareAlarm (26)
Probable cause:
bootLoaderVersionMismatch (118)
Severity: Critical
Object Type (class):
ControlProcessor
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when there is a
mismatch between the firmware
version and the software image on an
NE. The alarm information includes
the discovered and expected version
identifiers.
Name: BrokenLoop
Type: configurationAlarm (11)
Probable cause: stackNotInLoop (355)
Severity: Major
Object Type (class):
StackConfiguration
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
loop-detection stack detects a loop
condition, or when the stack
contains an unexpected element.
Alarm Attributes Additional information
(3 of 14)
Aug 2010
AAAD
8.0 R4

Table of Contents