3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-33
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Name: LowTemperatureThresholdCrossed
Type: environmentalAlarm (2)
Probable cause: equipmentOvercooled
(838)
Severity: Major
Object Type (class): Environment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a
temperature crosses a threshold.
Name: PowerSupplyVoltageAlarm
Type: equipmentAlarm (3)
Probable cause: powerSupplyFailure (117)
Severity: Info
Object Type (class): PowerSupply
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the
associated power supply alarm
voltage state is not set to Normal.
Name: RetimingBufferOverFlow
Type: communicationsAlarm (4)
Probable cause: bufferOverFlow (839)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an retiming
buffer overflow occurs.
Name: UnderlyingResourceUnavailable
Type: communicationsAlarm (4)
Probable cause:
underlyingResourceUnavailable (724)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an
underlying resource is unavailable on
an E1, radio, or Ethernet interface.
Name: BackgroundDiagnosticFault
Type: equipmentAlarm (3)
Probable cause: backgroundDiagnosticFault
(353)
Severity: Minor
Object Type (class): ReplaceableUnit
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an NE
detects a failure in a background
diagnostic test suite.
Name: BatmDsx1CurrentCSSs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of far-end Controlled Slip
Seconds crosses the threshold.
Name: BatmDsx1CurrentESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of far-end Errored Seconds
crosses the threshold.
Name: BatmDsx1CurrentLESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of Line Errored Seconds
crosses the threshold.
Name: BatmDsx1CurrentPVCs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of Path Coding Violations
crosses the threshold.
Name: BatmDsx1CurrentSEFSs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of far-end Severely Errored
Framing Seconds crosses the
threshold.
Name: BatmDsx1CurrentSESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the current
number of far-end Severely Errored
Seconds crosses the threshold.
Alarm Attributes Additional information
(2 of 14)