3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-37
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Name: DDMRxOpticalPowerHighAlarm
Type: thresholdAlarm (49)
Probable cause: rxOpticalPowerHighAlarm
(377)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
received optical power of an SFP or
XFP reaches the maximum threshold
value.
Name: DDMRxOpticalPowerHighWarning
Type: thresholdAlarm (49)
Probable cause:
rxOpticalPowerHighWarning (376)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
received optical power of an SFP or
XFP approaches the maximum
threshold value.
Name: DDMRxOpticalPowerLowAlarm
Type: thresholdAlarm (49)
Probable cause: rxOpticalPowerLowAlarm
(375)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
received optical power of an SFP or
XFP reaches the minimum threshold
value.
Name: DDMRxOpticalPowerLowWarning
Type: thresholdAlarm (49)
Probable cause: rxOpticalPowerLowWarning
(374)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
received optical power of an SFP or
XFP approaches the minimum
threshold value.
Name: DDMSupplyVoltageHighAlarm
Type: thresholdAlarm (49)
Probable cause: supplyVoltageHighAlarm
(365)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the supply
voltage of an SFP or XFP reaches the
maximum threshold value.
Name: DDMSupplyVoltageHighWarning
Type: thresholdAlarm (49)
Probable cause: supplyVoltageHighWarning
(364)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the supply
voltage of an SFP or XFP approaches
the maximum threshold value.
Name: DDMSupplyVoltageLowAlarm
Type: thresholdAlarm (49)
Probable cause: supplyVoltageLowAlarm
(363)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the supply
voltage of an SFP or XFP reaches the
maximum threshold value.
Name: DDMSupplyVoltageLowWarning
Type: thresholdAlarm (49)
Probable cause: supplyVoltageLowWarning
(362)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the supply
voltage of an SFP or XFP approaches
the maximum threshold value.
Name: DDMTemperatureHighAlarm
Type: thresholdAlarm (49)
Probable cause: temperatureHighAlarm
(361)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of an SFP or XFP
reaches the maximum threshold
value.
Alarm Attributes Additional information
(6 of 14)