3 — Troubleshooting using network alarms
3-38 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Name: DDMTemperatureHighWarning
Type: thresholdAlarm (49)
Probable cause: temperatureHighWarning
(360)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of an SFP or XFP
approaches the maximum threshold
value.
Name: DDMTemperatureLowAlarm
Type: thresholdAlarm (49)
Probable cause: temperatureLowAlarm
(359)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of an SFP or XFP
reaches the maximum threshold
value.
Name: DDMTemperatureLowWarning
Type: thresholdAlarm (49)
Probable cause: temperatureLowWarning
(358)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of an SFP or XFP
approaches the maximum threshold
value.
Name: DDMTxBiasCurrentHighAlarm
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentHighAlarm
(369)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
transmit bias current of an SFP or
XFP reaches the maximum threshold
value.
Name: DDMTxBiasCurrentHighWarning
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentHighWarning
(368)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
transmit bias current of an SFP or
XFP approaches the maximum
threshold value.
Name: DDMTxBiasCurrentLowAlarm
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentLowAlarm
(367)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
transmit bias current of an SFP or
XFP reaches the maximum threshold
value.
Name: DDMTxBiasCurrentLowWarning
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentLowWarning
(366)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
transmit bias current of an SFP or
XFP approaches the maximum
threshold value.
Name: DDMTxOutputPowerHighAlarm
Type: thresholdAlarm (49)
Probable cause: txOutputPowerHighAlarm
(373)
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the output
power of an SFP or XFP reaches the
maximum threshold value.
Name: DDMTxOutputPowerHighWarning
Type: thresholdAlarm (49)
Probable cause:
txOutputPowerHighWarning (372)
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the output
power of an SFP or XFP approaches
the maximum threshold value.
Alarm Attributes Additional information