3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-41
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Name: FanFailure
Type: equipmentAlarm (3)
Probable cause: fanFailure (116)
Severity: Critical
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
associated fan is not operationally
up.
Name: FanTrayRemoved
Type: equipmentAlarm (3)
Probable cause: FanTrayRemoved (438)
Severity: Critical
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
deviceState attribute has a value of
deviceNotEquipped.
Name: FIBHighOccupancy
Type: resourceAlarm (28)
Probable cause: FIBHighOccupancy (528)
Severity: Warning
Object Type (class): BaseCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FIB
occupancy on an IOM card changes
from normal to high.
Name: FibOutOfSynch
Type: resourceAlarm (28)
Probable cause: fibUpdateFailed (464)
Severity: Critical
Object Type (class): DaughterCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FIB on
an MDA is out of synchronization.
Name: FirmwareDownloadOnGoing
Type: equipmentAlarm (3)
Probable cause: firmwareDownloadOnGoing
(465)
Severity: Warning
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a firmware
download is in progress.
Name: FirmwareMismatchAlarm
Type: firmwareAlarm (26)
Probable causes:
bootRomVersionMismatch (119)
fpgaVersionMismatch (120)
Severity: Critical
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a device
detects a mismatch between the
firmware version and the device
software image. The alarm
information includes the expected
firmware version.
Name: FirmwareUpgradeAlarm
Type: firmwareAlarm (26)
Probable cause: firmwareUpgraded (169)
Severity: Info
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when a device
automatically upgrades the firmware
of a hot-inserted IOM or CPM.
Name: HardwareRedundancyAlarm
Type: equipmentAlarm (3)
Probable cause: primaryCpmFailure (121)
Severity: Major
Object Type (class):
ControlProcessor
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the primary
CPM fails.
Name: InternalCommunicationProblem
Type: equipmentAlarm (3)
Probable cause:
internalCommunicationProblem (466)
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ODU is
unresponsive.
Name: LagPortAddFailed
Type: equipmentAlarm (3)
Probable cause: linkDown (315)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the Lag Port
Add function Fails.
Name: LanFailure
Type: equipmentAlarm (3)
Probable cause: lanFailure (467)
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a LAN
failure is detected.
Alarm Attributes Additional information
(10 of 14)
Aug 2010
AAAD
8.0 R4