3 — Troubleshooting using network alarms
3-42 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Name: LinkDown
Type: communicationsAlarm (4)
Probable cause: portLinkProblem (10)
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a port has
no associated physical link.
Name: LossOfAlignment
Type: communicationsAlarm (4)
Probable cause: lossOfAlignment (468)
Severity: Minor
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a Loss of
Alignment signal is detected.
Name: LossOfFrame
Type: communicationsAlarm (4)
Probable cause: lossOfFrame (97)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a port
receives a Loss Of Frame signal.
Name: LossOfSignal
Type: communicationsAlarm (4)
Probable cause: lossOfSignal (99)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a Loss of
Signal signal is detected on a PDH
tributary.
Name: MigrationCompleted
Type: migrationComplete (62)
Probable cause: migrationComplete (529)
Severity: Info
Object Type (class):
NeCardSwapTask
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when a card
migration event completes.
Name: MigrationFailed
Type: migrationFailure (63)
Probable cause: migrationFailure (530)
Severity: Major
Object Type (class):
NeCardSwapTask
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when a card
migration event fails.
Name: OutOfSlots
Type: configurationAlarm (11)
Probable cause: noAvailableSlotNumbers
(352)
Severity: Major
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when a stack
element enters pass-through mode
because there is no slot number for
the element.
Name: OverTemperatureDetected
Type: environmentalAlarm (2)
Probable cause: equipmentOverheated (5)
Severity: Major
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the chassis
temperature exceeds the maximum
threshold value.
Name: PChipCAMEvent
Type: hardwareAnomaly (55)
Probable cause: camError (577)
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an IOM or
CPM experiences a P-chip CAM error.
Name: PChipError
Type: hardwareAnomaly (55)
Probable cause: pChipError (447)
Severity: Warning
Object Type (class): BaseCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a P chip
reports persistent errors on the
specified complex in the specified
direction.
Alarm Attributes Additional information