EasyManua.ls Logo

Ametek RS90-3Pi - Option -WHM: Watt Hour Measurement; Figure 9-43: Application Screen; Figure 9-44: Watt-Hour Meter Screen; Figure 9-45: WH-Meter Screen with Function Active

Ametek RS90-3Pi
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual AMETEK Programmable Power
RS Series 215
9.10 Option –WHM: Watt Hour Measurement
9.10.1 General
This section describes the WHM option available for the RS Series Power Source.
9.10.2 Specification
All specifications are the same as the standard RS Power Source specifications in addition to
the following specifications:
Watt-hour
0-6.000KW 0.2%FS +0.1%R <100 Hz
0.5%FS +0.1%R 100-819 Hz
>6.000KW Times three of the above specification
9.10.3 Local Operation
From the Menu screen 2, select the APPLICATIONS SETUP 2 screen. The screen will appear
as shown in Figure 9-43. Use the up and down key to position the cursor to the WH METER
field. Press the Enter Key.
Figure 9-43: Application Screen
The WATT-HOUR METER screen shown in Figure 9-44 has the following fields:
Figure 9-44: Watt-Hour Meter Screen
1. START: This field will activate the watt-hour measurements. Moving the shuttle clockwise when the
field is highlighted will activate the watt-hour function and the field will change to STOP as shown in
Figure .
2. ETIME: This field will accumulate the time in hours, minutes and seconds.
3. WATT HR: This field will accumulate the watt-hour in KWH.
4. POWER: This field will report the instantaneous power in KW.
5. PK CURR: This field will report the peak current and will hold the maximum reading.
Figure 9-45: WH-Meter Screen with Function Active

Table of Contents