EasyManuals Logo

Ametek RS90-3Pi User Manual

Ametek RS90-3Pi
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
User Manual AMETEK Programmable Power
RS Series 83
REPEAT This is the number of times the VOLTAGE SWEEP/STEP
transient event will repeat before it will proceed to the next
event or exit the transient program. Note that the number of
times the transient event is generated is equal to the REPEAT +
1. Leave this value at zero if only one execution of this event in
the list is required.
EVENT # This must be the last item in the transient edit screen. All data
fields must be entered before inserting the EVENT #. The
EVENT # takes a value from 1 to 99. The EVENT # defines the
order of execution of the transient events in a multiple event
transient. It is a good practice to enter spaced EVENT #’s to
allow insertion of an EVENT later if needed. (For example,
space them by 5.) Entry of a sequence EVENT # number will
cause the display to return to the TRANSIENT screen.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek RS90-3Pi and is the answer not in the manual?

Ametek RS90-3Pi Specifications

General IconGeneral
BrandAmetek
ModelRS90-3Pi
CategoryPower Supply
LanguageEnglish

Related product manuals