Clean filters cartridges.
At the end of each spraying operation it is necessary to clean the tank level sensor.
1) Tank level sensor
2) Drain tap
Follow this procedure:
Main tank must be empty
Open the drain tap (2)
Put some clean water inside main tank and let it out of drain tap
Continue this flushing for some seconds
Close drain tap (2)
It is possible to spray flush water to the vegetation object of the spray application.
Do NOT waste chemicals residuals directly in the environment.
It is mandatory to collect residuals in adequate containers and bring to the authorised center
according to laws in force.
Always use adequate individual protective devices (glasses, gloves, masks, cloths, etc.) when
handling chemicals and when performing flushnig operations.