ANDREOLI ENGINEERING
Operator’s Manual
Self-propelled sprayer ATOM
62/166
3.12.8 Heating system layout
The following drawing explains the heating system layout installed on the machine:
1) Engine outlet safety manual tap
2) Control Tap (inside cab)
3) Heat exchanger (inside cab)
4) Engine inlet safety manual tap
Safety manual tap on engine outlet (1) and inlet (4) can be closed if any malfunction or leakage
is detected in the circuit.
Remember to keep them open when heating system is working.
If the machine is equipped with automatic A/C control,control tap inside cab (2) is an electric
type.
If the machine is equipped with manual A/C controls, control tap (2) is a manual type.
4
1
2
3