ANDREOLI ENGINEERING
Operator’s Manual
Self-propelled sprayer ATOM
Check suction hoses, suction filter
and pump suction manifold
Springs of pump valves broken or
worn out
Presence of dirt in pump valves
Excessive temperature of the
mixture
Presence of water in pump oil
Excessive vibrations on pump
pressure hoses
Pressure accumulator discharged
Check the pressure on the
accumulator and/or replace the
diaphragm
Valves worn out or obstructed
Blower fan does not start
Slow down revs below 1200 rpm
Electric connection faulty
Check and restore the connection
Non constant measurement of
spray rates
Negative hydraulic park brake
always on
Park brake hydraulic valve
damaged
Boost pressure of main pump too
low
Tires do not stay aligned
Presence of air in the steering
hydraulic circuit
Drain air out of the circuit
Steer rams seals worn out
Steer rams alignment valves
damaged
Set correct inflating pressure
Low pressure in steering circuit
Hydraulic steering gear worn out