ANDREOLI ENGINEERING
Operator’s Manual
Self-propelled sprayer ATOM
78/166
Mixer nozzle is controlled by a manual tap, placed on the pump:
1) Manual tap for mixer
To use the mixer you MUST have some water in the main tank.
To use the mixer:
Start the pump
Keep all nozzles sections closed
Put powder chemicals inside the basket
Close the lid
Activate the mixer using the manual tap (1)
Regulating the pressure you can adjust the mixing force, keeping under control foam generation.
Do NOT run the mixer with the lid open. Chemicals may be thrown out of the basket.
You MUST always wear protective devices when mixing chemicals.