MAINTENANCE
n
n
n
n
n
n
n
n
n
n
n
Short
Isolation
Procedure
This
procedure
contains
both
procedural
steps
and
questions.
Where
questions
are
asked,
responses
are
provided
for
both
YES
and
NO
answers.
1.
Turn
the
power
switch
OFF.
2.
Loosen
the
screws
securing
the
+5
and
GND
cables
to
the
power
supply
and
remove
the
cables.
3.
Attach
the
VOM
to
the
+5
and
GND
cables.
(Use
ohms
R
x
1
scale.)
4.
Does
the
meter
read
0
ohms?
YES
Continue.
NO
Return
to
"Power
Supply
Check."
5.
Remove
an
option
board
from
the
Bus
Converter
Board.
6.
Does
the
VOM
indicate
7
ohms
or
more
after
the
option
board
has
been
removed?
YES
Replace
the
option
board
just
removed
and
continue.
NO
Continue.
5-19