Version 5.8 139 September 2009
SIP User's Manual 3. Web-Based Management
3.3.4.8.5 Configuring the Internal SRV Table
The 'Internal SRV Table' page provides a table for resolving host names to DNS A-
Records. Three different A-Records can be assigned to each host name. Each A-Record
contains the host name, priority, weight, and port.
Notes:
If the Internal SRV table is configured, the device initially attempts to
resolve a domain name using this table. If the domain name isn't found,
the device performs an Service Record (SRV) resolution using an
external DNS server.
You can also configure the Internal SRV table using the ini file table
parameter SRV2IP (refer to ''DNS Parameters'' on page 223).
¾ To configure the Internal SRV table:
1. Open the 'Internal SRV Table' page (Configuration tab > Protocol Configuration
menu > Routing Tables submenu > Internal SRV Table page item).
Figure 3-80: Internal SRV Table Page
2. In the 'Domain Name' field, enter the host name to be translated. You can enter a
string of up to 31 characters long.
3. From the 'Transport Type' drop-down list, select a transport type.
4. In the 'DNS Name 1' field, enter the first DNS A-Record to which the host name is
translated.
5. In the 'Priority', 'Weight' and 'Port' fields, enter the relevant values
6. Repeat steps 4 through 5, for the second and third DNS names, if required.
7. Repeat steps 2 through 6, for each entry.
8. Click the Submit button to save your changes.
9. To save the changes so they are available after a hardware reset or power fail, refer to
''Saving Configuration'' on page 167.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals